IBEX’s cutting-edge range of 3D reconstruction, image enhancement, and scatter removal products, available now for integration

Reconstruction engine for Tomosynthesis and Cone Beam CT
Available now, IBEX RE is a advanced iterative 3D reconstruction engine that delivers outstanding images with reduced artefacts, lower noise, and reduced dose for all tomographic systems including DRT, DBT, and CBCT.


Flexible and novel geometries
Compatible with any source/detector trajectory
Linear and multi-array emitters, moving sources, and detectors supported
Scatter Correction
Estimates and corrects for scatter by simulating X-ray transport through the object.
Metal artefact reduction
Reduces shading and streaking artefacts from high-density metals


Metal Artefact Reduction for DBT
IBEX RE with advanced MAR vastly improves the visibility of anatomical structures in DBT such as micro-calcifications, fine detailed soft tissue structures, and masses, which can otherwise remain hidden.
The graphic demonstrates the power of IBEX RE with MAR to completely remove metal artefacts and reveal detail that was originally concealed.


Projecting CT volume data
into Digital Radiographs
IBEX Augmented X-ray combines unique elements of AI with classical image processing and advanced post-processing to deliver unlimited 2D Radiographs from any 3D volume with no added dose.

Bridging the gap between CT
and general radiology
IBEX AX offers fast and reliable 2D reconstruction from captured 3D data. The cutting-edge software also incorporates AI-automated foreign object removal that removes casts, supports, and metal implants, allowing for clearer anatomical viewing.


With limitless viewing options from any angle or orientation, this state-of-the-art technology provides clinicians with fast and automatic 2D visualisation of CT volume data, creating the potential for easier surgical planning and faster diagnosis.


Multi-modality physics-based gridless scatter correction
Proven in clinical applications including Mobile DR, CBCT, and Mammography, the state-of-the-art IBEX SC scatter correction software is a powerful alternative to physical grids.


Fixed and Mobile DR
IBEX SC has been successfully evaluated in an ITU setting and provides better tube and line visibility without the complication of grid alignment.
The software supports a wide range of viewing conditions, protocols and patient sizes.


Mammography
Compatible with all breast sizes and densities, IBEX SC offers grid equivalent performance in FFDM with standard screening and diagnostic protocols supported.
The technology also provides improved image quality in DBT offering better global contrast. Local contrast boosts provide better tissue discrimination in thicker breasts.


Cone Beam CT
Improved HU uniformity, improved bone and soft tissue contrast, and reduced shading artefacts.